The Baseline® 9000 Methane / Non-Methane Analyzer uses a flame ionization detector (FID) in conjunction with an oxidation catalyst switched in and out of the sample stream. The catalyst oxidizes all hydrocarbons except methane to produce a methane only measurement. This catalytic reaction relies on the presence of oxygen (O2) in the sample. The methane value is then subtracted from the total hydrocarbon concentration to determine the non-methane hydrocarbon reading. Output options include analog, digital and logic capabilities.
Our methane and non-methane analyzer provides fast data handling and highly reproducible results. Errors commonly associated with catalyst characteristics have been eliminated providing an extremely stable and accurate signal. Because the non-methane signal is the difference in the two measured quantities, it is more stable, thus greatly reducing its systemic zero drift. The non-methane signal response factor is adjusted and thus closely correlates to the carbon number. This analytic method eliminates integration errors that can be present in gas chromatographic (GC) methods.
The Baseline® 9000 Methane / Non-Methane Analyzer can be configured with internal components for single or multi-point analysis of non-condensing gas samples. The automatic calibration feature enhances the long-term analytical stability of the instrument.
The instrument provides access to operating parameters and concentration data through an RS-232 or Ethernet port. A simple ASCII, tab delimited protocol has been implemented. The ASCII data can be acquired by an external PC running a basic communications program such as Windows® Hyper Terminal or the analyzer can output binary or ASCII formats directly to a data acquisition system or PLC. Every Baseline® 9000 analyzer includes AMETEK MOCON's free PC utility 9000 Keeper used for storing and uploading multiple methods, as well as sending configuration settings, directly to the analyzer.
Automated Control Features
- FlowGuard control of fuel, air, and sample with automatic shut-off
- Automatic FID ignition
- Electronic back-pressure regulator with sample bypass system
- Automatic calibration at user-defined intervals
- Automatic adjustment for catalyst efficiency variance
Versatile Platform
- Graphic LCD display with easy to use menu
- Benchtop or rack-mountable
- Single or multi-point sampling
- Customizable ethernet or serial output
- Programmable analog output ranges
- Programmable relays for diagnostics, concentration, alarms, and events
Baseline® 9000 Methane/Non-Methane Analyzer
|
Units
|
Detector
|
Flame Ionization (FID) w/ oxidizer
|
Ranges
|
User definable based upon calibration (as methane):
Ambient version:
- Low – 0.03 ppm to 50 ppm
- Medium – 0.06 ppm to 500 ppm
- High – 0.15 ppm to 5000 ppm
120°C version:
- Low – 0.06 ppm to 50 ppm
- Medium – 0.6 ppm to 500 ppm
- High – 1.0 ppm to 5000 ppm
|
Accuracy, Repeatability
|
±1% full-scale
|
Drift, Zero
|
±0.01% full-scale, 24 hours
|
Drift, Span
|
±1% full-scale, 24 hours
|
Response Time
|
Response Time T90 < 30 seconds
|
Sampling
|
Internal single point, pump optional
|
Alarms
|
Multilevel concentration and fault alarms, audible and visual
|
Calibration
|
Programmable automatic or manual calibration
|
Support Gas Requirement
|
Support Gas Requirement UHP Hydrogen (H2) – 35 cc/min
Zero Air – 175 cc/min
Span gas – methane/propane is typical
Fuel blend options available
|
Display
|
Graphical LCD, 3.4” x 4.5” (8.64 cm x 11.43 cm)
|
Outputs, Standard
|
RS-232
LAN/Ethernet
Analog, 1 programmable 0-20mA/4-20mA isolated output
Relays, 5 programmable Form A relays rated to 3A @230VAC
|
Outputs, Optional
|
3 additional Analog outputs
5 additional Relays
|
Operating Temperature
|
32 to 104°F (0 to 40°C)
|
Operating Humidity
|
0 to 95% (non-condensing)
|
Configuration
|
Benchtop or 19” (48.3cm) rack-mount, 3U
|
Other Specifications (all models):
Physical Specifications
- 5.25” H x 19” W x 16.25” D (13.02 cm x 48.26 cm x 41.28 cm)
- <20 Lbs. (9.07 kg)
Electrical Requirements
- Voltage: 100 - 240 VAC 50/60 Hz, 1 A
Preventive Maintenance Kit
- Includes all parts potentially needed on-hand
Gas Generators
- Hydrogen generators
- Zero Air generators
Software
- 9000 Keeper provided for method switching
Service & Support Options
- Start-up and training, 1 day onsite
Environmental Monitoring
- AMC in Cleanrooms
- Air Quality Monitoring
- Fugitive Emission Monitoring
Toxic Gas Monitoring
- Indoor Air Quality
- Leak Detection
- OEM PID Sensors
Industrial Process Analysis & Control
- Beverage Gas Monitoring
- Industrial Gas Mixing Control
- Process Gas Analysis
- Specialty and Industrial Gas Monitoring
- Surface Logging Analysis